Approved Document Part G(England) and Approved Document G (Wales) provides that adequate and suitable sanitary conveniences should be provided in rooms provided to accommodate them.

The use of a macerator and pump allows for an extra toilet to be provided in places such as under the stairs, basements or to a bathroom.

Whiledrainage is covered in Approved Document Hthere are clauses in Part G that cover the appliances that discharge to the drainage system.

Parapgraph 4.25(a) (England) and 4.24(a) (Wales) of Approved Document G permits the use of a macerator as long as there is also a WC discharging to a gravity system.

In all cases both are required to discharge to an adequate drainage system.

Approved Document G then gives further guidance for the installation of a WC fitted with a macerator as follows:

If you are looking to specify or install a macerator then the system needs to comply to at least one of these Standards.

Once installed, the installation will need to be used and maintained in accordance with the manufacturers recommendations, some of the common recommendations include:

In hard water areas limescale will build up and will eventually cause the macerator to fail.

One manufacturer recommends the use of a phosphoric acid (a mineral (inorganic) and weak acid having the chemical formula H3PO4). If the manufacturers instructions are followed, it is claimed that it can remove tough limescale, prolong the life of the unit and keep it running smoothly.

When specifying the units, potential owners should be aware of the ongoing maintenance costs, the electrical supply costs and noise that can be generated when the pump operates.

(Image courtesy ofhttp://hps.plentech.com)


Disclaimer:

Every care has been taken to ensure that the above content is correct at the time of publication. Any reliance on the content should be verified by the dutyholder(s) and their professional advisers. It is the responsibility of the dutyholder(s) and/or person carrying out the work to ensure compliance with the relevant building regulations and associated legislation.

This content is given in good faith by LABC. It is not definitive, and compliance will be a matter for the relevant building control authority to decide as the enforcing body for the building regulations, and ultimately for the appropriate tribunal or court to determine.

LABC Application and use of Member Guidance Notes LABC is a membership organisation, providing guidance and support to its member local authorities around England and Wales. LABC is unable to comment on the application and enforcement of the Building Regulations or other building safety related legislation to a particular proposal, as this is a matter for the local authority in whose jurisdiction the building work is being carried out or, in the case of High-Risk Buildings (HRBs), the Building Safety Regulator (BSR) and for the courts to rule upon.

TT_103.1

This article was originally published on the LABC website on 20/11/2018. View the original article.