Navigation

Underpinning of existing foundations

Did you know that underpinning of foundations is notifiable work under the Building Regulations? You must make an application to the building control authority in all cases, without exception.

If the underpinning works are to be carried out adjacent or in close proximity to another existing building, you need to ensure your client complies with the requirements of the Party Wall etc Act 1996 by advising them to enter into a party wall agreement with the adjoining owner.

Where a building has been damaged by foundation movement and has required underpinning, there may also be a need to carry out structural repairs or strengthening work to the superstructure. Such works should be designed and specified by a competent structural engineer or a specialist structural repair company.

Mass concrete underpinning

The most common method is traditional mass concrete underpinning - a simple technique that involves excavating a segment of ground below the existing building foundation in controlled stages, to a depth where suitable bearing strata exists.

The excavation is then filled with concrete and allowed to cure before the next 'pin'is excavated. To transfer the building load safely to the new pin, a dry sand cement packing mortar is rammed in between the new and old foundation.Each pin is typically connected with multiple reinforcement bars, which are driven into the sides of the excavations prior to pouring the concrete.

This method is suitable for shallow depth underpinning. Work can be carried out from one side of the wall and in areas of difficult and restricted access. It is suitable for heavy foundation loads and massive structures and for the formation of new cellars and basements beneath existing buildings.

Points to remember

The majority of reputable underpinning contractors offer a 10-year defects insurance guarantee that applies to underpinning, mini piling and foundation works. This is operated by the Association of Specialist Underpinning Contractors. A list of its members is available from www.asuc.org.uk


Disclaimer:

Every care has been taken to ensure that the above content is correct at the time of publication. Any reliance on the content should be verified by the dutyholder(s) and their professional advisers. It is the responsibility of the dutyholder(s) and/or person carrying out the work to ensure compliance with the relevant building regulations and associated legislation.

This content is given in good faith by LABC. It is not definitive, and compliance will be a matter for the relevant building control authority to decide as the enforcing body for the building regulations, and ultimately for the appropriate tribunal or court to determine.

TT_9.1

This article was originally published on the LABC website on 12/11/2018. View the original article.