One of our surveyors had a bit of a shock recently when visiting a site for a domestic extension.

They were called out to inspect reinforcement prior to concreting foundations but hadnt been to site previously for an excavation or commencement inspection. The builder proudly stood back and informed the officer that he had dug down 450mm but was still into filled ground so had decided to construct a reinforced raft foundation instead.

Better still, he was helping the environment by recycling shopping trolleys for the reinforcement.

"Every little helps" replied a bemused officer before explaining what was wrong. The project was subsequently abandoned because of the additional cost of doing it correctly and it reverted back to a patio area.

If youre involved in constructing a raft foundation then there are some key factors that need to be considered to ensure that the reinforcement fabric is correctly installed. Its an alternative if you cant use a traditional strip or trench fill foundations but it's important to note that raft foundations arent suitable in all cases and usually need designing by a competent structural engineer.

Unlike suspended floors or strip foundations where mesh is just placed in the bottom of the concrete to act in tension, rafts usually have mesh in the top to resist compression from heavy point loads like internal walls and in the bottom for tension to spread the load across a wider surface.

Reinforcement key points

Foundation reinforcement table

Application (concrete position)Minimum cover
(mm)
Concrete in direct contact with the ground75
All external applications e.g. shuttered walling50
Floor slabs and other applications where concrete is cast onto a membrane40
Concrete over blinding40
Internal conditions25

Table courtesy of LABC Warranty Technical Manual (version 10)

Please note: LABC do not advocate the use of shopping basket/trolley mesh in foundations!


Disclaimer:

Every care has been taken to ensure that the above content is correct at the time of publication. Any reliance on the content should be verified by the dutyholder(s) and their professional advisers. It is the responsibility of the dutyholder(s) and/or person carrying out the work to ensure compliance with the relevant building regulations and associated legislation.

This content is given in good faith by LABC. It is not definitive, and compliance will be a matter for the relevant building control authority to decide as the enforcing body for the building regulations, and ultimately for the appropriate tribunal or court to determine.

LABC Application and use of Member Guidance Notes LABC is a membership organisation, providing guidance and support to its member local authorities around England and Wales. LABC is unable to comment on the application and enforcement of the Building Regulations or other building safety related legislation to a particular proposal, as this is a matter for the local authority in whose jurisdiction the building work is being carried out or, in the case of High-Risk Buildings (HRBs), the Building Safety Regulator (BSR) and for the courts to rule upon.

TT_106.1

This article was originally published on the LABC website on 07/08/2018. View the original article.